Video Files Of FireStopper Firefighting Catalyst In Use
These videos are large and should be downloaded or viewed with at least T1, Cable modem or DSL speeds.
Portuguese Air Force - March 2007 - Jet A using
FireStopper @ 6% to extinguish in 32 Seconds.

Gulp Energy - March 2007 - Gasoline and Naphtha.
Portuguese Navy - 1% FireStopper AB FFC on Diesel
Chevron Refinery - 300 Gallons of High-test Gasoline. FireStopper AB at 6% was used.
Effective on Class A as shown in this video of a 1A Crib.
| ETech Modular Firefighting Systems |
![]() Self Activating Fire Systems |
| Video 1
Confined Space System on 28 oz. Gasoline w/1L Modular System. Agent: FireStopper FR FFC (operational to -100 F) (NOTE: not a foam) |
| System
Demo 1-05-07 Self activating 15 Liter system demonstrating 12 fog
nozzles. This system can use up to 20 nozzles and can
contain up to 100 US gallons. Agent: FireStopper XL, FR or AB FFC. |
NOTE: These systems can be reset and recharged in under 1 minute. (Modular Canister) |
Fire
Extinguisher Training on a tire.
FireStopper in Pressurized Water Extinguisher @ 6%, used by an inexperienced
layman. An engineer we were working
with wanted to experience FireStopper on tires. This video is the
result. Note: Only a small fraction of the extinguisher was used.
This
video is of a fire department that is inexperienced in the use of FireStopper.
When properly trained, a fire like this can be completely
extinguished in about two minutes verses the 6 minutes in the video.
Equipment:
·
One pumper truck
·
One 1.5 “ ATTACK LINE with a turbo nozzle
·
3 men
·
7 Gallons of FireStopper ® AB 40002 FFC Concentrate @ 6%
Fuel:
·
115 semi-truck tires accelerated with 10 gallons of
gasoline and diesel fuel


Tank
Explosion Suppression Video
Power Point presentation made by British MOD on the tests.
(More details available)
BSI_EN3_Class_A_Certification_43A.mpg
AB 40002 FFC display's its tremendous capabilities on a class A
fire attack used through a 9 liter portable extinguisher @ 6%. The size of the wood crib was 4.3 miters long and
qualified the product under BSI EN3 as a 43A classification.
Fire
Dept_House fire_attack with FireStopper_6%_9Liter extinguisher
This demonstration and fire exercise was conducted by Fire Department in
North Carolina using FireStopper ® .
The training exercise demonstrates the enormous fire-fighting and
suppression capabilities of AB 40002 FFC.
Equipment:
·
One 9-liter water extinguisher with FireStopper @
6%, a standard
strait stream nozzle and pressurized to manufacturer spec's
Fuel:
·
Class A materials: box-spring and mattress, pallets
representing furniture and hey representing carpet material
· Class B materials: one quart of Diesel/Gasoline fuel was thrown onto the established fire a few seconds before extinguisher attack on the fire.
Exercise: 10,000 SF Training Exercise
Fuel: JP4 (Running fuel fire)
Media: 6% FireStopper AB 40002 FFC
Equipment: 2 1.5" Hoses with Akron Turbo Nozzles
Fire Extinguishment Duration: 19 Seconds
Repsol Refinery Training on running fuel fire.
Fuel: Naptha
Equipment: 2 1.5" hand lines with Akron Turbo Nozzles.
Media: FireStopper AB at 6%
British MOD Aircraft Fire Training
1 Liter Modular Fire Extinguisher on 5B Fire (950ml actual)
Fuel: 12.5 Gallons of Heptane
Media: FireStopper PFE
1 Liter Modular Fire Extinguisher on Class K Fire
Fuel: 11 Gallons Vegetable Oil
Media: FireStopper PFE

Fuel: 25 Gallons Diesel Fuel
Media: FireStopper AB 40002 FFC @ 6%
Nozzle: Akron 1" Turbo
LAMAR
UNIVERSITY (Texas)
Equipment:
·
The equipment used was one 1 1/2” line with an
Akron Challenger aspirating nozzle at 95 psi.
(Recommended at 125 psi)
Fuel:
·
September 2002 – this clip demonstrates
FireStopper® attacking a 3 dimensional pit at Lamar University.
The fuel used was E-3, a highly refined, smokeless form of naphtha. This
fuel is only in use at Lamar University and Texas A&M for training purposes.
Total fuel used was 300 gallons of E-3.
This same pit was extinguished previous to this video with a full 3D running
fire using three Akron Turbo
Size of pit:
·
24' x 24' (576 Square Feet)
For Additional Information Contact: William Davis at wed@firestopper.us or 904-334-4407 or 800-853-9509.